36
© 2003 directed electronics, inc.
ffeeaattuurree ddeessccrriippttiioonnss
11 EENNGGIINNEE CCHHEECCKK OONN//OOFFFF
: In the default setting the
remote start will monitor either the vehicle's tach wire or voltage
depending on the programming of Feature 2. If programmed
off, the vehicle will crank for the programmed crank time
(Feature 5) and will not verify with tach or voltage that the
vehicle is running. In the off setting, if the vehicle fails to start,
the ignition can stay on for the entire run duration. Using tach
or voltage check is always recommended if possible.
22 TTAACCHH WWIIRREE SSEENNSSEE//VVOOLLTTAAGGEE SSEENNSSEE::
If the tachometer
signal wire is used, this feature must be left in the default (tach
wire connected) setting. If programmed to the voltage sense
setting, the unit will crank the starter for a preset time that can
be programmed in Feature 5. Once the starter has been engaged,
the system will check the voltage level to verify the engine is
running. The threshold for the voltage level test can be
programmed in Feature 6. When using voltage sense mode,
connection of the H2/5 VIOLET/ WHITE tachometer input is
not necessary.
33 RRUUNN TTIIMMEE 1122//2244//6600 MMIINNUUTTEESS::
This feature controls how
long the engine will run before it “times out” and shuts down.
Programmed to the default setting the engine will run for 12
minutes. If the 24 or 60 minute run time is desired, change this
feature to the two or three flash setting.
Page view 38